4500 High Cpu Action Plan.No.1

Config “no ip unreachables” and “no ip redirects” in all L3 interface or SVI. General the “ip unreachables” and “ip redirects” will affect cpu utilization in 4000/4500. So if  don’t requirement for “ip unreachables” and “ip redirects”. Suggest to turn off the feature first. Then confirm the problem will be clear.
关于redirect的内容,可以参考之前的文章《ICMP 重定向的一些问题》和《Layer 3 层网络中的重定向》 ,另外官网也有详细介绍: When Are ICMP Redirects Sent?

4500 High Cpu Action Plan.No.2

If the cpu couldn’t downgrade, then capture follow information:

#clear counters 
#show int switching  //some times #show ip int
#show proc cpu sorted | exclude 0.00
#show proc mem sorted
#show platform health
#show platform cpu packet statistics all

完整阅读

Upgrade XR for ASR9k/CRS/GSR by TURBOBOOT

[对于XR的升级,就我现在所知的有以下几种,如果还有其他的方法,到时再更新]
1. Golden Disk升级
类似于Ghost系统,在现有XR设备(version A)上直接把整个系统文件backup到disk卡中,然后把这个disk卡放到要升级的机箱上(version B),指定boot位置并重启,就可以直接用新系统了(version A)。省了安装系统的时间。但由于需要指定boot路径,另外还需要copy MBI文件到bootflash,所以操作起来感觉不是非常方便。

2013-9-18 更新:
在2010-9-24 更新中的第3和第4小点中,已经总结了一些GoldenDisk的内容。这里再提一下,如果从老版本升级到新版本,如3.6.3到4.0.4,又需要用FAT32,那么一定要把MBI拷贝到bootflash,否则无法识别FAT32;另外还要记住升级前要升级rommona/b的版本,原因下面有解释。

在3.6.3上升级rommon的步骤如下:
1. 从官网下载较新的rommon tar文件
2. 拷贝到disk0中
3. 执行upgrade rommon a/b all disk0

如果客户安装了很多SMU,又不知道正确的MBI路径,那么可以在老系统中把默认的MBI路径拷贝到bootflash中,然后启动,设备会自动boot这个MBI,如果MBI不正确,它会自动把正确的MBI文件copy到bootflash中,然后重启并用新MBI启动,如下所示:

Install (Node Preparation): Booting with committed software
Install (Node Preparation): Checking free space on /bootflash/
Install (Node Preparation): Copying MBI from /disk0/hfr-os-mbi-4.0.4.CSCuc17728-1.0.0/mbihfr-rp.vm
Install (Node Preparation): Copying MBI to /bootflash/disk0/hfr-os-mbi-4.0.4.CSCuc17728-1.0.0/mbihfr-rp.vm
insthelper: This node was booted with an incorrect MBI (/bootflash/disk0/hfr-os-mbi-4.0.4/mbihfr-rp.vm), rebooting self with correct boot image (/bootflash/disk0/hfr-os-mbi-4.0.4.CSCuc17728-1.0.0/mbihfr-rp.vm).

2. Turboboot 升级
完全重新安装,在Rommon模式中download mini PIE文件,感觉像之前IOS环境下的启动新版本那样。只不过XR是要安装,而IOS直接调用。
3. 直接在原有系统上升级
打个比方说,在windows xp的基础上直接升级到windows 7,这样即使windows 7装完了,在新系统中仍然有老系统的东西。所以一般不推荐用这种方法。对于disk存储介质,最好只有1种操作系统,这样稳定些。

2013-11-29 更新:
在现有系统升级又分两种方式:
一种是直接安装PIE文件,如果你的版本是A,要升级B,那么直接active B的PIE即可,但要注意,A和B的PIE要保持一致才能安装,否则会有兼容,如下所示(注:现有系统升级后,配置是保留的):

RP/0/RP0/CPU0:LAB-CRS-1(admin)#show ins ac sum
Wed Nov 20 08:56:25.113 UTC
Default Profile:
  Admin Resources
  SDRs:
    Owner
  Active Packages:
    disk0:hfr-mpls-px-4.0.4
    disk0:hfr-mgbl-px-4.0.4
    disk0:hfr-mini-px-4.0.4

RP/0/RP0/CPU0:LAB-CRS-1(admin)#install activate disk0:hfr-mini-px-4.2.4 sync
Wed Nov 20 08:56:33.503 UTC
Install operation 34 '(admin) install activate disk0:hfr-mini-px-4.2.4 synchronous' started by user 'cisco' via CLI at 08:56:33 UTC Wed Nov 20 2013.
Error:    Cannot proceed with the activation because of the following package incompatibilities:
Error:      hfr-mgbl-supp-4.0.4 needs iosxr-fwding-4.0.4, or equivalent, to be active on the same nodes.
Error:      hfr-mgbl-supp-4.0.4 needs hfr-fwding-4.0.4, or equivalent, to be active on the same nodes.
Error:      hfr-mgbl-supp-4.0.4 needs hfr-base-4.0.4, or equivalent, to be active on the same nodes.
Error:      hfr-mgbl-supp-4.0.4 needs iosxr-infra-4.0.4, or equivalent, to be active on the same nodes.
Error:      hfr-mgbl-supp-4.0.4 needs hfr-os-support-4.0.4, or equivalent, to be active on the same nodes.
Error:      hfr-mgbl-supp-4.0.4 needs iosxr-os-4.0.4, or equivalent, to be active on the same nodes.
Error:      iosxr-mgbl-4.0.4 needs iosxr-routing-4.0.4, or equivalent, to be active on the same nodes.
Error:      iosxr-mgbl-4.0.4 needs iosxr-fwding-4.0.4, or equivalent, to be active on the same nodes.
Error:      iosxr-mgbl-4.0.4 needs iosxr-infra-4.0.4, or equivalent, to be active on the same nodes.
Error:      iosxr-mgbl-4.0.4 needs iosxr-os-4.0.4, or equivalent, to be active on the same nodes.
Error:      iosxr-mpls-4.0.4 needs iosxr-routing-4.0.4, or equivalent, to be active on the same nodes.
Error:      iosxr-mpls-4.0.4 needs iosxr-fwding-4.0.4, or equivalent, to be active on the same nodes.
Error:      iosxr-mpls-4.0.4 needs iosxr-infra-4.0.4, or equivalent, to be active on the same nodes.
Error:      iosxr-mpls-4.0.4 needs iosxr-os-4.0.4, or equivalent, to be active on the same nodes.
Error:    Suggested steps to resolve this:
Error:     - check the installation instructions.
Error:     - activate or deactivate the specified packages on the specified nodes.
Install operation 34 failed at 08:56:40 UTC Wed Nov 20 2013.
RP/0/RP0/CPU0:LAB-CRS-1(admin)#
RP/0/RP0/CPU0:LAB-CRS-1(admin)#install add tftp://10.75.41.57/hfr-mgbl-px.pie-4.2.4 sync
Wed Nov 20 08:57:39.796 UTC
Install operation 35 '(admin) install add /tftp://10.75.41.57/hfr-mgbl-px.pie-4.2.4 synchronous' started by user 'cisco' via CLI at 08:57:39 UTC Wed Nov 20 2013.
Info:     The following package is now available to be activated:
Info:
Info:         disk0:hfr-mgbl-px-4.2.4
Info:
Info:     The package can be activated across the entire router.
Info:
Install operation 35 completed successfully at 08:58:02 UTC Wed Nov 20 2013.
RP/0/RP0/CPU0:LAB-CRS-1(admin)#install activate disk0:hfr-mini-px-4.2.4 disk0:hfr-mgbl-px-4.2.4 sync
Wed Nov 20 08:58:46.818 UTC
Install operation 36 '(admin) install activate disk0:hfr-mini-px-4.2.4 disk0:hfr-mgbl-px-4.2.4 synchronous' started by user 'cisco' via CLI at 08:58:46 UTC Wed Nov 20
2013.
Error:    Cannot proceed with the activation because of the following package incompatibilities:
Error:      iosxr-mpls-4.0.4 needs iosxr-routing-4.0.4, or equivalent, to be active on the same nodes.
Error:      iosxr-mpls-4.0.4 needs iosxr-fwding-4.0.4, or equivalent, to be active on the same nodes.
Error:      iosxr-mpls-4.0.4 needs iosxr-infra-4.0.4, or equivalent, to be active on the same nodes.
Error:      iosxr-mpls-4.0.4 needs iosxr-os-4.0.4, or equivalent, to be active on the same nodes.
Error:    Suggested steps to resolve this:
Error:     - check the installation instructions.
Error:     - activate or deactivate the specified packages on the specified nodes.
Install operation 36 failed at 08:58:54 UTC Wed Nov 20 2013.
RP/0/RP0/CPU0:LAB-CRS-1(admin)#
RP/0/RP0/CPU0:LAB-CRS-1(admin)#install deactivate disk0:hfr-mpls-px-4.0.4
Wed Nov 20 08:59:20.777 UTC
Install operation 37 '(admin) install deactivate disk0:hfr-mpls-px-4.0.4' started by user 'cisco' via CLI at 08:59:20 UTC Wed Nov 20 2013.
Info:     Install Method: Parallel Process Restart
The install operation will continue asynchronously.
RP/0/RP0/CPU0:LAB-CRS-1(admin)#show ins ac sum
Wed Nov 20 09:00:36.442 UTC
Default Profile:
  Admin Resources
  SDRs:
    Owner
  Active Packages:
    disk0:hfr-mgbl-px-4.0.4
    disk0:hfr-mini-px-4.0.4

RP/0/RP0/CPU0:LAB-CRS-1(admin)#
RP/0/RP0/CPU0:LAB-CRS-1(admin)#install activate disk0:hfr-mini-px-4.2.4 disk0:hfr-mgbl-px-4.2.4 sync
Wed Nov 20 09:00:50.380 UTC
Install operation 38 '(admin) install activate disk0:hfr-mini-px-4.2.4 disk0:hfr-mgbl-px-4.2.4 synchronous' started by user 'cisco' via CLI at 09:00:50 UTC Wed Nov 20
2013.
Info:     This operation will reload the following nodes in parallel:
Info:         0/7/CPU0 (LC) (SDR: Owner)
Info:         0/15/SP (MSC-DRP-SP) (Admin Resource)
Info:         0/15/CPU0 (LC) (SDR: Owner)
Info:         0/RP0/CPU0 (CRS16-RP-x86) (SDR: Owner)
Info:         0/FC0/SP (SP) (Admin Resource)
Info:         0/FC1/SP (SP) (Admin Resource)
Info:         0/AM0/SP (SP) (Admin Resource)
Info:         0/AM1/SP (SP) (Admin Resource)
Info:         0/SM2/SP (140G-Fabric-SP-B) (Admin Resource)
Info:         0/SM3/SP (140G-Fabric-SP-B) (Admin Resource)
Info:         0/SM4/SP (140G-Fabric-SP-B) (Admin Resource)
Info:         0/SM5/SP (140G-Fabric-SP-B) (Admin Resource)
Info:         0/SM6/SP (140G-Fabric-SP-B) (Admin Resource)
Info:         0/SM7/SP (140G-Fabric-SP-B) (Admin Resource)
Proceed with this install operation (y/n)? [y]
Info:     Install Method: Parallel Reload
Info:     The changes made to software configurations will not be persistent across system reloads. Use the command '(admin) install commit' to make changes persistent.
Info:     Please verify that the system is consistent following the software change using the following commands:
Info:         show system verify
Info:         install verify packages
Install operation 38 completed successfully at 09:06:24 UTC Wed Nov 20 2013.
RP/0/RP0/CPU0:LAB-CRS-1(admin)#

另一种方式是直接安装下载后的TAR文件,或者自己做的一个TAR文件,以后有机会抓着部分信息,在更新上去。

关于rommon的一些问题
CRS一共有两个rommon,rommon A和rommon B。平时启动都是rommon B,rommon A只做一些工厂检测用。[如果rommon A的版本不低于1.52(这是CRS的需求,9k的另需要确认),就不用升级rommon A。因为每次启动都会由rommon A 去disk卡中check一些信息,感觉像是rommon在加载一些命令集(monlib ?),使得如果rommonB不能启动,或是坏了,可以直接从rommon A启动进行检测。如果版本低于1.52,rommon A就会不识别fat32的disk,所以就停在那里无法继续进行加载rommon B,如果是fat16,就没有任何问题]
完整阅读

ATM基础知识 2 信元的结构

在ATM基础知识中,对ATM涉及的一些基本概念做了解释,在这里,我将对ATM信元的结构进行详细分析。我画了一张简图,如下所示,可以很容易看出ATM的层次及信元的组成:

完整阅读

Agilent 建立BGP邻居及打流量

[虽然Agilent已经被IXIA收购有一段时间了,但公司里仍然还有Agilent的设备,有时还是需要用到的,之前一直在用Agilent打流量,感觉挺好使的,但很少用它打路由,最近正好做了一些测试,这里把Agilent的使用方法简单说明下,以备日后复习。另外公司Agilent的版本是6.7,5年前的东西了,所以不支持大规模更改路由(拿BGP来说,如果你有100个neighbor,你需要每个neighbor上打10条路由,那么这时你只能一个neighbor一个neighbor添加路由,没办法统一修改),只有升级到6.12以后才支持此功能。]

1. 连接好Agilnewent端口后,通过“mstsc”登录到Agilent上,点击添加端口(第一次登录会默认让用户去设置端口)

完整阅读

QOS之CBWFQ与LLQ简要说明

[关于QOS的东西,一直想总结下,但QOS东西很多,也不好整理,最近同事问到一个问题,正好复习了下,索性记录下来,已做日后参考。下面的测试是比较基础的,不涉及GSR,CRS,9k以及交换机的硬件QOS,很多中高端设备的QOS是由硬件做的,根据平台的不同,也不尽相同,本篇文档不做介绍。]

Topology:

PC(10.1.11.1.1)–(10.11.1.2)router1(f1/0)–(f1/0)router2(lo1,lo2,lo3)
完整阅读